📝 Extracted Text (OCR)
From: LO KELVIN

To: WAINWRIGHT RON

Ce: PUDER AUSTEN

Subject: RE: Spot Sampling for OMC1 Training Room
Date: January 26, 2026 2:14:00 PM
Attachments: image001.pna

Hello Ron,

Austen requested a spot sampling for OMC1 Control Room today, this was done at 2:00 PM on Jan
26, 2026.

Please see the results we got:
1. Workstations: average around 56-58 dBA
2. Ambient Working Environment: average around 50-70dBA
@ 50 dBA when the room was silent (no communication happening)
@ Peak at 70dBA when there are communication happening through the speakers
3. Server rack behind workstation: average around 62-65 dBA

Similarly, all these values were below the occupational exposure limit of 85 dBA - TWA (8-hours),
although we did not measure for 8 hours, we are assuming the noise does not fluctuate much.

Thanks,

KELVIN LO

Senior Safety Advisor
Railway Safety and Security
P: 604-218-0128

E: kelvin lo@bertc.bc.ca

BC Rapid Transit Company (BCRTC)
6800 14th Ave, Burnaby, BC V3N 487, Canada

From: WAINWRIGHT RON <RON_WAINWRIGHT @bertc.bc.ca>
Sent: January 23, 2026 1:39 PM

To: LO KELVIN <KELVIN_LO@BCRTC.BC.CA>

Subject: Re: Spot Sampling for OMC1 Training Room

Thanks Kelvin

From: LO KELVIN <KELVIN_LO@BCRTC.BC.CA>

Sent: January 23, 2026 10:36

To: WAINWRIGHT RON <RON_WAINWRIGHT@bertc.bc.ca>
Ce: TENG ELIOT <ELIOT_ TENG@BCRTC.BC.CA>

000194