The internal RSS department conducted preliminary spot sampling on January 23, 2026, around the workstation and adjacent server rack: Location / Condition Measured Noise Level Workstations 56-58 dBA Ambient environment (typical) 50-70 dBA Room silent (no communication) 50 dBA Room peak during active communication | Up to 70 dBA Server rack behind workstation 62-65 dBA OEL for reference 85 dBA TWA (8-hour limit) Key Finding: All values were well below the 85 dBA 8-hour TWA limit, even though the sampling was not over a full shift. Noise levels inside the room were consistent with normal office or equipment room environments. Third-Party Noise Assessment: Acrose Consulting Ltd. BCRTC commissioned Acrose Consulting Ltd. to complete an independent noise survey. The full report will be attached in the official submission. Their work included: e Spot noise measurements e Long-term data logging e Noise mapping of the room e Final report with recommendations 5.1. Summary of Acrose Findings Initial spot measurements: e Highest reading in the training simulation room: 65.7 dBA e Peak level recorded: 89.3 dBC Data-logged measurement (7:34 AM - 4:12 PM; 8h 38m): e Projected 10-hour TWA: 57.6 dBA e Maximum recorded peak: 86.7 dBC 000293